Librería Samer Atenea
Kálamo Books
Librería Elías (Asturias)
Librería Kolima (Madrid)
Librería Proteo (Málaga)
In Benin, the policy for the biological screening of blood bags collected from donors favors pooled testing conducted at CDTSs, which are equipped with ELISA systems and automated analyzers. Pending the widespread implementation of this policy, serological marker screening is still performed in several blood collection centers using rapid tests, particularly in centers that are isolated or located far from CDTS facilities. The objective of our study was to evaluate HIV serological screening among blood donors at the blood collection centers in Comé, Gohomey, and Klouekamey. The results of this study show that the DETERMINE reagent used in all three blood transfusion centers yielded a false-negative rate of 0.6%, with a specificity of 100% and a negative predictive value of 99.4%, indicating that its performance is insufficient, particularly for blood transfusion centers.